Some install the Ice and Water underlayment, then a layer of Rosin Paper before installing the Copper. Copper Roofing needs only a Rosin Slip Sheet under it, but it needs to be isolated from acidic underlayments. If the roofer wants to install an asphalt paper under the metal to give another barrier for migrating moisture before a potentially ... WIP underlayments offer excellent protection against water and ice damming while withstanding some of Nature's most unfavorable weather conditions. The self-adhering qualities of WIP underlayments reduce labor costs and installation times while providing increased protection compared to that of typical felt roofing underlayments.
Grace Ice & Water Shield is UL classified under all classified shingxles for use in detail areas or for full roof coverage. Grace Ice & Water Shield is the only membrane underlayment with a fire rating for internal fire resistance. Longest Performance History Grace Ice & Water Shield offers the longest performance history and the
Ice and water shield installation diagram
Guidelines to Follow When Installing an Ice and Water Shield — Install your ice and water protector covering at least 3 feet from the edge of your ... Install Ice and Water Shield at all eaves, valleys and around projections that are greater than 12″x 12″ (recommended.) Felt underlayment should not be placed under the ice and water shield, but should overlap the ice and water shield no less than 3″. Side laps should be no less than 6". How To Flash A Deck Ledger Board. First I like to install a layer of self adhering bitchathane (we like Grace Ice and Water) behind the ledger and above it by at least 12 inches. Make sure the bitchathane is behind the house wrap. The house wrap should extend and overlap the bitchathane.
Ice and water shield installation diagram. Jul 08, 2019 · The below diagram helps outline exactly how to determine how much ice & water shield is needed on any given roof above 4/12 pitch. Note: on roofs with a pitch lower than 4/12 but greater than 2/12, this requirement changes and the roof must entirely be covered with ice & water shield before asphalt shingles can be applied. Here's how… Proper installation of Grace Ice & Water Shield® The Conventional Method Cut the membrane into 3-5 m (10-15 ft.) lengths and re-roll loosely. Peel back 300-600 mm (1-2 ft.) of release liner, align membrane. Peel the release liner from the membrane. Press the membrane in place with heavy hand pressure. WeatherLock® Flex Flexible Self-Sealing Ice & Water Barrier provides excellent roof deck protection against water infiltration resulting from the freeze/thaw cycle, wind-driven rains and normal water flow around eaves, rakes, valleys, vents, chimneys and skylights. High performance - Flexible and pliable poly surface and modified asphalt ... GRACE ICE & WATER SHIELD® protects a homeowner's roof from the damaging effects of water intrusion due to wind-driven rain and ice dams because it: Fully adhered roofing underlayment sticks aggressively to deck surface. Forms a watertight seal around fasteners used to install shingles and other roof coverings.
The first underlayment is a waterproof ice and water membrane that is installed along the perimeter on the roof to protect a roof from ice damming (in snow-zone areas) - read more on ice dams HERE - as well as areas where roof planes meet to form valleys, which naturally channel high water flow in wet weather and other roof penetrations such as ... The flashing shall be a minimum of 4 inches (102 mm) high and 4 inches (102 mm) wide. At the end of the vertical sidewall the step flashing shall be turned out in a manner that directs water away from the wall and onto the roof and/or gutter.". While this is a nice diagram of how these flashings work don't forget our 5 th design rule…. Line the center of the valley with a row of ice and water shield (width may vary) Install metal flashing on top of the ice and water shield. Sandwich the metal with the second row of water and ice shield. Cut the shingles along the line created by this new row of ice and water shield, leaving the metal open to channel water off the roof. WeatherMaster ® Ice & Water is a composite roof underlayment designed to provide a secondary waterproofing barrier needed to prevent ice dams and damage from wind-blown rain.. A proprietary fiberglass mat reinforced, SBS-modified asphalt makes WeatherMaster ® Ice & Water ideally suited for continuous waterproofing protection against ice dams and wind-blown rain year after year.
special adhesives, heat or equipment for installation. USES Guardian Roof ArmorTM Poly Ice & H20 is an excellent underlayment for metal roofs, designed to prevent moisture entry into structures by sealing uniformly to the deck and around nail penetrations. Guardian Roof ArmorTM Poly Ice & H2O can serve as a temporary roof to protect the ... Ice and water shield is perfect to use around skylights, chimneys, plumbing vents, ventilation caps, or anything that penetrates up through a roof. The roofer laps the material up onto the object and cuts it at corners or curves in a special way to create a leak-proof barrier. ice and watershed 2. 3. grace ice and watershield or equal may be used as a substitute ... ice and watershield may be installation instructions. cable with wall panel cable underlayment roo s underlayment. note required reference 0 berridge manufacturing company distinction . Ice and water protector is part of a system working together to protect your roof, including the shingles and other underlayments. To learn more about water and ice shield, or to have it installed on your roof, please visit our Contractor Locator to find a local roofer in your area.
A typical snow and ice protective shield is shown below, but other methods may be used per the guidelines listed in the notes below the picture. Notes: 1. The shield must be constructed to handle the force of falling ice/snow from a given height. 2. A metal shield should be constructed, primed, and painted with a minimum of 10 gauge metal. 3.
Following installation, please forward this manual to the appropriate operations person. 12 Series Ice and Water Dispensers Order parts online www.follettice.com 12CI400A-LI countertop, ice-only dispenser 12CI400A-SI countertop, ice-only dispenser with SensorSAFE™ infrared dispensing 208595R21 801 Church Lane • Easton, PA 18040, USA
installation manual 6 zip system ® sheathing and tape contents continued . wood shingles . alternative details . pipe boots 52 . ice and water membranes . 53 h-clips . 54 pipe boots 55 . drip edge 56 . toe boards 57 . valley flashing 58 . ridge 59 . common fixes. small holes . 61 large holes . 62 saw kerfs . 64 chips in the overlay . 65 siding ...
One person can install long lengths of ice and water shield to the roof, however it is easier for two people to install, especially with some new installatio...
In areas where there has been a history of ice forming along the eaves causing a backup of water, an ice barrier shall be installed for asphalt ... Building Code 2018 of Illinois > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.1 Scope > 1507.1.2 Ice Barriers
19. Attach stainless steel shield to side of condenser shroud using provided screws. 20. Re-install all baffles, panels and covers. 21. Re-install unit into built-in or free-standing location. ENSURE THAT NO KINKS OCCUR IN WATER INLET OR DRAIN TUBING. Double-check for leaks! 22. Restore potable water supply and restart the unit.
Figure 7 - Installation of WaterGuard Rain & Icein a Roof Valley Using Application Method #2 Subsequent installation of underlayment on the field of the roof can be laced across roof valleys and up the adjacent roof a minimum of 6" or lapped 6" onto the membrane valley liner. EAVE METAL Figure 6 - Typical Application of WaterGuard Rain & Ice
In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in Table R301.2(1), an ice barrier that consists of not less than two layers of underlayment cemented together or of a self-adhering polymer-modified bitumen sheet shall be used in lieu of normal underlayment and extend from the ...
Install the ice barrier first with the drip edge over the top, then apply a 4- to 6-inch-wide self-adhering "stripping ply" to bridge over the top of the drip edge and onto the ice barrier. The stripping-sheet method relies on the adhesive bond of the stripping ply to seal out water.
Founded in 1963, ATAS International, Inc. is a leading manufacturer of metal wall cladding, metal roofing, ceilings, perimeter edge metal, and accessories. T...
The ice and water shield starting at the eave must be installed sufficiently to where it effectively covers to an invisible vertical line that would be two feet to the exterior wall line of the building. (If the property has a history of ice damming and heavy snow loads additional coverage of water proof underlayment would be recommended.) 3 ...
Ice & water shield is a thick, sticky-back underlayment (also known as felt paper) that will adhere to your roof deck and prevent water from seeping into your home if it gets under your shingles. If an ice dam occurs on your roof and water backs up under the shingles it will seep down into your home through the nail holes holding the shingles ...
How To Flash A Deck Ledger Board. First I like to install a layer of self adhering bitchathane (we like Grace Ice and Water) behind the ledger and above it by at least 12 inches. Make sure the bitchathane is behind the house wrap. The house wrap should extend and overlap the bitchathane.
Install Ice and Water Shield at all eaves, valleys and around projections that are greater than 12″x 12″ (recommended.) Felt underlayment should not be placed under the ice and water shield, but should overlap the ice and water shield no less than 3″. Side laps should be no less than 6".
Guidelines to Follow When Installing an Ice and Water Shield — Install your ice and water protector covering at least 3 feet from the edge of your ...
Comments